technical data sheet rpc-1.85 mismatch plug 08S150-075S3 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 email : info@rosenberger.de page 1 / 2 rf_35/09.14/6.2 dieses dokument ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg all dimensions are in mm; tolerances according to i so 2768 m-h interface according to iec 61169-32 mechanically compatible with rpc-2.40 documents application note an001 calibration services material and plating connector parts material plating center contact cube gold, min. 1.27 m, over nicke l outer contact stainless steel passivated coupling nut stainless steel passivated dielectric ps substrate al 2 o 3
technical data sheet rpc-1.85 mismatch plug 08S150-075S3 rosenberger hochfrequenztechnik gmbh & co. kg p.o.box 1260 d-84526 tittmoning germany www.rosenberger.de tel. : +49 8684 18-0 email : info@rosenberger.de page 2 / 2 rf_35/09.14/6.2 dieses dokument ist urheberrechtlich geschtzt this document is protected by copyright rosenberger hochfrequenztechnik gmbh & co. kg electrical data frequency range dc to 70 ghz vswr 1.5 0.07, dc to 26.5 ghz 1.5 0.18, 26.5 ghz to 70 ghz dc resistance 75 w 0.375 w power handling 0.5 w mechanical data mating cycles 3 500 maximum torque 1.65 nm recommended torque 0.90 nm gauge 0.00 mm to 0.03 mm environmental data operating temperature range 1 + 20 c to +26 c rated temperature range of use 2 0 c to +50 c storage temperature range - 40 c to +85 c rohs compliant 1 temperature range over which these specification ar e valid. 2 this range is underneath and above the operating te mperature range, within the mismatch is fully funct ional and could be used without damage. declaration of calibration options factory calibration standard delivery for this calibration standard inc ludes a factory calibration. the calibration certif icate issued reports individual calibration results, trac eable to national / international standards. model based standard definitions are reported in an agilent/key sight, rohde & schwarz and anritsu compatible vna format. accredited calibration not available. for further, more detailed information see applicat ion note an001 on the rosenberger homepage. calibration interval recommendation 12 months packing standard 1 pce in box weight 7.2 g/pce draft date approved date rev. engineering change n umber name date marion striegler 29.01.14 markus mller 12.09.16 c 00 16-1390 marion striegler 12.09.16 while the information has been carefully compiled to the best of our know ledge, nothing is intended as representation or war ranty on our part and no statement herein shall be construed as recommendation to infringe existing patents. in the effort to improve our products, we reserve the right to make changes judg ed to be necessary.
|